EMS/TENS Devices
-
-
Digital Tens/EMS +37P
The EV-906 Digital TENS/EMS is a battery operated pulse generator that sends electrical impulses electrodes to the body and reach the nerves and underlying muscle group. This unit is a combination stimulator of TENS and EMS which can be used for muscle stimulation and pain relief. The device is provided with four controllable output channels, each independent of each other. An electrode pair can be connected to each output channel. The intensity level is controlled by press buttons.
MECHANISM
TECHICAL DESCRIPTION
01
Channel
Four, isolated between channels
02
Pulse Amplitude
Adjustable, 0-100 mA peak into 500 ohm load each channel.
03
Wave Form
Asymmetrical Bi-Phasic Square Pulse
04
Voltage
0 to 50V (Load: 500 ohm)
05
Power source
Four 1.5V AA batteries
06
Size
13.8cm(L) x 7.8cm(W) x 2.8cm(H)
07
Weight
425 grams with battery
08
Pulse Rate
Adjustable, from 2 to 150 Hz, 1 Hz/step
09
Pulse Width
Adjustable, from 50 to 300 microseconds, 10 µs/step
10
On Time
Adjustable, 2~90 seconds , 1 Sec./ step
11
Off Time
Adjustable, 0~90 seconds , 1 Sec./ step
12
Ramp Time
Adjustable, 1~8 seconds, 1 Sec./ step, The "On" time will increase and decrease in the setting value.
13
Mode
Five TENS Modes: B(Burst), N(Normal),M (Modulation),
SD1( Strength Duration), SD2 Three EMS Modes:C(Constant) S (Synchronous), A(Alternate)
14
Burst Mode(B)
Burst rate: Adjustable, 0.5 ~ 5Hz
Pulse width adjustable, 50~300µs
Frequency fixed = 100 Hz15
Normal Mode(N)
The pulse rate and pulse width are adjustable. It generates continuous stimulation based on the setting value.
16
Modulation Mode(M)
Modulation mode is a combination of pulse rate and pulse width modulation. The pulse rate and width are automatically varied in a cycle pattern. The pulse width is decreased by 50% from its original setting in 0.5 second, then the pulse rate is decreased by 50% from its original setting in 0.5 second.Total cycle time is 1 second. In this mode, pulse rate(2-150Hz) and pulse width(50-300µs) are fully adjustable.
17
SD1 Mode
The SD1(Strength-Duration) mode consists of automatic modulation intensity and pulse width in 40% range. The intensity is always increasing while the pulse width is decreasing and vice-versa. The intensity is decreased by 40% while the pulse width is increased by 40% in 5 seconds. In the next 5 seconds, the intensity is increased by 40% while the pulse width is decreased by 40%.Total cycle time is 10 seconds. Pulse rate ( 2~150Hz) and pulse width (50~300µs) are fully adjustable.
18SD2 ModeThe SD2(Strength-Duration) mode consists of automatic modulation intensity and pulse width in 70% range. The intensity is always increasing while the pulse width is decreasing and vice-versa. The intensity is decreased by 70% while the pulse width is increased by 70% in 5 seconds. In the next 5 seconds, the intensity is increased by 70% while the pulse width is decreased by 70%.Total cycle time is 10 seconds. Pulse rate( 2~150Hz) and pulse width (50~300µs) are fully adjustable.19Constant Mode (C)Constant stimulation based on setting value. Only pulse width, pulse rate and timer are adjustable in this mode. "Constant" is equal o the"Normal" mode of a TENS unit.20Synchronous Mode (S)
Stimulation of both channels occurs synchronously. The "ON" time including "Ramp Up" and "Ramp Down" time. Therefore, the setting of ON Time should be no less than two times of the "Ramp" time in this mode. ON TIME≥Ramp up + Ramp down21Alternate Mode(A)The stimulation of the CH2 will occur after the 1st contraction of CH1 is completed. In this mode, the setting of ON Time should be no less than two times of the "Ramp" time. The OFF Time should be equal or more than the ON Time.
ON TIME ≥;Ramp up + Ramp down OFF TIME ≥IN TIME22TimerTwo Adjustable timers, from 1 to 60 minutes or Continuous. Adjustable in 1 minute each step from 1 to 15 minutes, and 5 minutes each step from 15 to 60 minutes. Treatment time countdown automatically.23Patient Compliance Meter
This unit can store 60 sets of operation records. Total recorded time is 999 hours.24Low Battery Indicator
A low battery indicator will show up when the battery is low.25Operating ConditionTemperature:0°~40°
Relative Humidity: 30%~75%
Atmosphere Pressure : 700Hpa~1060Hpa26RemarkThere may be up to a +/-5% tolerance of all parameters and +/-20% tolerance of amplitude & voltage.
Features
Precise Intensity Control
There are 100 steps of intensity level controlled by press buttons from 1 to 100mA.
Press Button Control
The power, intensity level and parameter are controlled by press buttons, which is easy for the users to adjust the settings. All of the buttons are protected by a swing door to avoid accidental touch.
Large Liquid Crystal Display
A large LCD in 6.1 x 4.4 cm showing the intensity level, settings and treatment timer. The selected modes and parameters are readable.
Two Treatment Timers
There are two individual timers controlling the output of CH1, CH2 & CH3, CH4. This function is ideal when two patients accept treatment with the same machine.
Treatment Time Countdown
The output will shut off automatically when time is up.
Compliance Meter
The unit can store 60 sets of record of operation.Add to Cart$250.00 -
Rectal Electrode ProbeDiameter: 19.6MM
Length: 110MM
With 2 rings PIGAIL connectionAdd to Cart$56.00 -
WHITE INTELLIGENT NECK MASSAGER
Specifications:
• 4 Point Fit & Ergonomic Design: Fit the neck in all directions, comfortable to wear and more satisfying; Ergonomic Design conforms to the curve of the human neck.
• Infrared Light Heating: Around 107.3 ℉Constant Temperature for Muscle Tension Relaxation
• Heating Temperance: From 100.4 ℉ to 107.3 ℉
• Light Weight Design: Small and light, convenient and easy to carry
• Product Details: Stainless steel electorate sheet, 3D Circular elastic arm and Micro-Surface Design
• Color Options: Pearl White
• Size: 14.2x 14.5 x 4.5cm
• Accessories: USB-C Charging Port Convenient and Quick Charging
Key Features:
• Pulse Massage: 5 Pulse Modes including Tapping, Scraping, Acupuncture, Kneading and Free Combination
• 16 Levels of Intensity Adjustment: Level 1-5 Comfortable for Neck Relaxation; Level 6-10 Moderate for Relieving Soreness; Level 11-16 Stimulus for Deep Massage.
• Working Duration Time: 15 minutes timer
• Quick Charging, Ultra-long Run Time: 1.5 Hours Charge & 1200mAh Lithium Battery℉
K3 Intelligent 4 point fit Neck Massager adopts with human body cervical physiological curvature of the popular type circular design. Using low-frequency pulse, infrared light heating, U-Shaped Design, Ergonomic design and 3D intelligent bonding technology to form a composite energy field to achieve tetras health care and fit the neck in all directions, comfortable to wear and more satisfying. During the working process, maintaining the correct physiological position to provide healthy and cosy therapy for the cervical spine. With Neck Massager, you can enjoy a more valuable, relaxed and happy multifunctional health care system at any time and anywhere.
Add to Cart$69.00 -
Digital TENS/EMS Premier Combo Plus+24PThe Premier Stim Plus TENS/EMS is a fully digital battery operated pulse generator that sends electrical impulses to the nerves and underlying muscle groups. This unit is a combination stimulator of TENS and EMS which can be used for pain relief and muscle stimulation. The device is provided with two controllable output channels, each independent of the other. A pair of electrodes can be connected to each output channel. The intensity level and settings are controlled by press buttons.
Accessories:- Adhesive Electrodes 4 pcs
- Electrodes Leads 2 pcs
- 9V Battery 1 pcs
- Blue Carrying Case 1 pcs
- English Operation Manual 1 pcs
- AC Power Cord 1 pcs
- Tens Electrodes Placement Chart 1 pcs
MECHANISM
TECHICAL DESCRIPTION
01
Channel
Dual, isolated between channels
02
Pulse AmplitudeAdjustable, 0-110 mA peak into 500 ohm load each channel. 03
Wave FormAsymmetrical Bi-Phasic Square Pulse 04
Voltage0 to 55V (Load: 500 ohm) 05
Power sourceOne 9 Volt Battery. 06
Size11.8cm(L) x 6 cm(W) x 3.1cm(H) 07
Weight157 grams with battery. 08
Pulse RateAdjustable, from 2 to 150 Hz, 1 Hz/step 09
Pulse WidthAdjustable, from 50 to 300 microseconds, 10 µs/step 10
On TimeAdjustable, 2~90 seconds , 1 Sec./ step 11
Off TimeAdjustable, 2~90 seconds , 1 Sec./ step 12
Ramp TimeAdjustable, 1~8 seconds, 1 Sec./ step, The "On"time will increase and decrease in the setting value. 13
ModeSix TENS Modes: B(Burst), N(Normal),M (Modulation Rate & Width),S1( Modulation Width), S2 (Modulation Width) and P Three EMS Modes:C(Constant), S (Synchronous), A(Alternate) 14
Burst ModeBurst rate: Adjustable, 0.5 ~ 5Hz
Pulse width adjustable, 50~300 µs
Frequency fixed = 100 Hz15
Normal ModeThe pulse rate and pulse width are adjustable. It generates continuous stimulation based on the setting value. 16
Modulation ModeModulation mode is a combination of pulse rate and pulse width modulation. The pulse rate and width are automatically varied in a cycle pattern. The pulse width is decreased by 50% from its original setting in 0.5 second, then the pulse rate is decreased by 50% from its original setting in 0.5 second. Total cycle time is 1 second. In this mode, pulse rate(2-150Hz) and pulse width(50-300µs) are fully adjustable. 17
S1 ModePulse width is automatically varied in a cyclic pattern over a nominal 10 second period. Pulse width decreases over a period of 4 seconds from the initial setting to a value 40% less.
The narrower pulse width continues for 1 second. It then increases over a period of 4 seconds to its initial setting. The cycle is then repeated. Pulse rate and pulse width are fully adjustable.18S2 ModePulse width is automatically varied in a cyclic pattern over a nominal 10 second period. Pulse width decreases over a period of 4 seconds from the initial setting to a value 70% less.
The narrower pulse width continues for 1 second. It then increases over a period of 4 seconds to its initial setting. The cycle is then repeated. Pulse rate and pulse width are fully adjustable.19Constant Mode(C)The pulse rate and pulse width are adjustable. It generates continuous stimulation is delivered . 20Synchronous Mode(S)Output from both channels occurs synchronously. The "ON" time includes "Ramp Up" and "Ramp Down" time. Therefore, the setting of ON Time should be no less than two times of the "Ramp" time in this mode. 21Alternate Mode(A)The stimulation of the CH2 will occur after Mode(A) the 1st contraction of CH1 is completed. In this mode, the setting of ON Time should be no less than two times of the "Ramp" time. The OFF Time should be equal to or greater than the ON Time.
ON TIME ≥ Ramp up + Ramp down
OFF TIME ≥ IN TIME22Mode PThe pre-set parameters of the 9 programs are as given below:
ProgramModePulse RatePulse WidthTimerP1Constant80Hz180µsContinueP2Burst100Hz
(Burst Rate:2Hz)180µsContinueP3-70% P.W.Modulation80Hz50µs-180µsContinueP4Mixed Frequency15Hz in 3 Sec
/2Hz in 3 Sec180µsContinueP5Mixed Frequency80Hz in 3 Sec /
2Hz in 3 Sec180µsContinueP6Constant10Hz180µsContinueP7Constant80Hz60µsContinueP8Constant80Hz180µs30 MinutesP9Burst100Hz(Burst Rate:2Hz)180µs30 Minutes23TimerAdjustable, from 5 to 60 minutes minutes and continue(C), 5 minutes each step. 24Patient
Compliance MeterThis unit can store 60 sets of operation records. Total recorded time is 999 hours. 25Low Battery IndicatorA low battery indicator will show up when the battery is low. 26Operating ConditionTemperature:0°~40°C
Relative Humidity: 30%~75%
Atmosphere Pressure : 700Hpa~1060Hpa27RemarkThere may be up to a +/-10% tolerance of all parameters and +/-20% tolerance of output amplitude & voltage. Add to Cart$135.00 -
Adhesive ElectrodesSelf-Adhesive Electrodes for:
- Transcutaneous Electrical Nerve Stimulator
- Electrical Muscle Stimulator
- Interferential StimulatorAdd to Cart$10.00 -
Pain Relief Tens Electrodes Refill KitThis Electrode Refill Kit is to be used with the TENS Unit.
The refill packages come with everything you see here. We recommend replacing the electrode pads once they do not stick well or they have been used for more than 30 days. The Refill package contains one conductive cable set (lead wire) and 3 sets of re-usable, latex-free electrode pads (6 individual pads).
The Refill Kit comes with:- 2" x 2" re-usable electrode pads (3 packages of 2)
- Conductive Cable (lead wire set)
Add to Cart$18.00 -
Incontinence Stimulator
The EM-2400 incontinence stimulator is a battery operated pulse generator that stimulates the muscles of the pelvic floor by means of a vaginal or rectal electrode. The unit has a single controllable channel which the electrode is connected to.
The stimulator has 5 preset programmes. The programme type and the intensity of stimulation are controlled by push buttons.
MECHANISM
TECHICAL DESCRIPTION
01
ChannelSingle channel 02
Pulse AmplitudeAdjustable, 0-80mA, Max output 80mA (peak to peak) into 500ohm load. 03
Output VoltageAdjustable, 0-40V, Max output 40V (peak to peak) into 500ohm load. 04
Wave FormAsymmetrical Rectangular Biphasic Pulse. 05
Power SupplyTwo AA Batteries 06
Size9.2cm(L) x 6.2cm(W) x 2.85cm(H) 07
Weight145 grams (2 batteries included) 08
Pulse RatePre-setting, 1~100 Hz 09
Pulse WidthPre-setting, 150 µs, 200 µs or 250 µs 10
ProgrammeA, B, C, D, E, five pre-set programme of options. 11
Programme
A ,B, C, EThe programme details of A, B, C, E are as follows. Parameters are preset at fixed values. The 2 seconds ramp time includes 1 second ramp up, and 1 second ramp down. Each programme is repeated in a constant cyclic pattern. ProgrammeRateWidthContractionRelaxationRampCycle(Hz)(µs)(Sec.)(Sec.)(Sec.)(Sec.)A3525048214B40200615223C1025053210E202505521212
Programme DProgramme D is composed of 12 sections with varied pulse rates. Each section contains 30 contractions. The 2 seconds ramp time includes 1 second ramp up, and 1 second ramp down. The complete programme lasts 60 minutes with 360 contractions. It is repeated in a constant cyclic pattern. The details of the programme are given below. SectionRateWidthContractionRelaxationRampCycle(Hz)(µs)(Sec.)(Sec.)(Sec.)(Sec.)1715044210281504421039150442104101504421051115044210612150442107131504421081415044210915150442101016150442101112150442101271504421013
TimerFixed at 30 minutes, treatment time countdown automatically. The output current will be shut off when the time is expired followed by a beep sound. 14
Operating ConditionTemperature:0° C ~ 40° C
Relative Humidity: 30%~75%
Atmosphere Pressure: 700Hpa~1060Hpa15
RemarkThere may be up to a +/-10% tolerance of all parameters and +/-20% tolerance of amplitude & voltage. Add to Cart$124.00