EMS/TENS Devices

Sort By:  
  • Vaginal Electrode Probe
    Diameter: 25MM
    Length: 145MM
    With 2MM PIGAIL connection
    Add to Cart
    $39.00
  • Digital Tens/EMS +37P
    The EV-906 Digital TENS/EMS is a battery operated pulse generator that sends electrical impulses electrodes to the body and reach the nerves and underlying muscle group. This unit is a combination stimulator of TENS and EMS which can be used for muscle stimulation and pain relief. The device is provided with four controllable output channels, each independent of each other. An electrode pair can be connected to each output channel. The intensity level is controlled by press buttons. 
     

     

    MECHANISM

    TECHICAL DESCRIPTION

    01

    Channel

    Four, isolated between channels

    02

    Pulse Amplitude

    Adjustable, 0-100 mA peak into 500 ohm load each channel.

    03

    Wave Form

    Asymmetrical Bi-Phasic Square Pulse

    04

    Voltage

    0 to 50V (Load: 500 ohm)

    05

    Power source

    Four 1.5V AA batteries

    06

    Size

    13.8cm(L) x 7.8cm(W) x 2.8cm(H)

    07

    Weight

    425 grams with battery

    08

    Pulse Rate

    Adjustable, from 2 to 150 Hz, 1 Hz/step

    09

    Pulse Width

    Adjustable, from 50 to 300 microseconds, 10 µs/step

    10

    On Time

    Adjustable, 2~90 seconds , 1 Sec./ step

    11

    Off Time

    Adjustable, 0~90 seconds , 1 Sec./ step

    12

    Ramp Time

    Adjustable, 1~8 seconds, 1 Sec./ step, The "On" time will increase and decrease in the setting value.

    13

    Mode

    Five TENS Modes: B(Burst), N(Normal),M (Modulation),

    SD1( Strength Duration), SD2 Three EMS Modes:C(Constant) S (Synchronous), A(Alternate)

    14

    Burst Mode(B)

    Burst rate: Adjustable, 0.5 ~ 5Hz
    Pulse width adjustable, 50~300µs
    Frequency fixed = 100 Hz

    15

    Normal Mode(N)

    The pulse rate and pulse width are adjustable. It generates continuous stimulation based on the setting value.

    16

    Modulation Mode(M)

    Modulation mode is a combination of pulse rate and pulse width modulation. The pulse rate and width are automatically varied in a cycle pattern. The pulse width is decreased by 50% from its original setting in 0.5 second, then the pulse rate is decreased by 50% from its original setting in 0.5 second.Total cycle time is 1 second. In this mode, pulse rate(2-150Hz) and pulse width(50-300µs) are fully adjustable.

    17

    SD1 Mode

    The SD1(Strength-Duration) mode consists of automatic modulation intensity and pulse width in 40% range. The intensity is always increasing while the pulse width is decreasing and vice-versa. The intensity is decreased by 40% while the pulse width is increased by 40% in 5 seconds. In the next 5 seconds, the intensity is increased by 40% while the pulse width is decreased by 40%.Total cycle time is 10 seconds. Pulse rate ( 2~150Hz) and pulse width (50~300µs) are fully adjustable.

    18
    SD2 Mode
    The SD2(Strength-Duration) mode consists of automatic modulation intensity and pulse width in 70% range. The intensity is always increasing while the pulse width is decreasing and vice-versa. The intensity is decreased by 70% while the pulse width is increased by 70% in 5 seconds. In the next 5 seconds, the intensity is increased by 70% while the pulse width is decreased by 70%.Total cycle time is 10 seconds. Pulse rate( 2~150Hz) and pulse width (50~300µs) are fully adjustable.
    19
    Constant Mode (C)
    Constant stimulation based on setting value. Only pulse width, pulse rate and timer are adjustable in this mode. "Constant" is equal o the"Normal" mode of a TENS unit.
    20

    Synchronous Mode (S)

    Stimulation of both channels occurs synchronously. The "ON" time including "Ramp Up" and "Ramp Down" time. Therefore, the setting of ON Time should be no less than two times of the "Ramp" time in this mode. ON TIME≥Ramp up + Ramp down
    21
    Alternate Mode(A)
    The stimulation of the CH2 will occur after the 1st contraction of CH1 is completed. In this mode, the setting of ON Time should be no less than two times of the "Ramp" time. The OFF Time should be equal or more than the ON Time. 
    ON TIME ≥;Ramp up + Ramp down OFF TIME ≥IN TIME
    22
    Timer
    Two Adjustable timers, from 1 to 60 minutes or Continuous. Adjustable in 1 minute each step from 1 to 15 minutes, and 5 minutes each step from 15 to 60 minutes. Treatment time countdown automatically.
    23

    Patient Compliance Meter

    This unit can store 60 sets of operation records. Total recorded time is 999 hours.
    24

    Low Battery Indicator

    A low battery indicator will show up when the battery is low.
    25
    Operating Condition

    Temperature:0°~40°
    Relative Humidity: 30%~75%
    Atmosphere Pressure : 700Hpa~1060Hpa

    26
    Remark
    There may be up to a +/-5% tolerance of all parameters and +/-20% tolerance of amplitude & voltage.

    Features
    Precise Intensity Control
    There are 100 steps of intensity level controlled by press buttons from 1 to 100mA. 
    Press Button Control
    The power, intensity level and parameter are controlled by press buttons, which is easy for the users to adjust the settings. All of the buttons are protected by a swing door to avoid accidental touch. 
    Large Liquid Crystal Display
    A large LCD in 6.1 x 4.4 cm showing the intensity level, settings and treatment timer. The selected modes and parameters are readable. 
    Two Treatment Timers
    There are two individual timers controlling the output of CH1, CH2 & CH3, CH4. This function is ideal when two patients accept treatment with the same machine. 
    Treatment Time Countdown
    The output will shut off automatically when time is up. 
    Compliance Meter
    The unit can store 60 sets of record of operation. 

     

    Add to Cart
    $250.00
  • Rectal Electrode Probe
    Diameter: 19.6MM
    Length: 110MM
    With 2 rings PIGAIL connection
    Add to Cart
    $56.00
  • WHITE INTELLIGENT NECK MASSAGER

    Specifications:
    • 4 Point Fit & Ergonomic Design: Fit the neck in all directions, comfortable to wear and more satisfying; Ergonomic Design conforms to the curve of the human neck.
    • Infrared Light Heating: Around 107.3 ℉Constant Temperature for Muscle Tension Relaxation
    • Heating Temperance: From 100.4 ℉ to 107.3 ℉
    • Light Weight Design: Small and light, convenient and easy to carry
    • Product Details: Stainless steel electorate sheet, 3D Circular elastic arm and Micro-Surface Design
    • Color Options: Pearl White
    • Size: 14.2x 14.5 x 4.5cm
    • Accessories: USB-C Charging Port Convenient and Quick Charging
     

    Key Features:
    • Pulse Massage: 5 Pulse Modes including Tapping, Scraping, Acupuncture, Kneading and Free Combination
    • 16 Levels of Intensity Adjustment: Level 1-5 Comfortable for Neck Relaxation; Level 6-10 Moderate for Relieving Soreness; Level 11-16 Stimulus for Deep Massage.
    • Working Duration Time: 15 minutes timer
    • Quick Charging, Ultra-long Run Time: 1.5 Hours Charge & 1200mAh Lithium Battery
    ℉
     

    K3 Intelligent 4 point fit Neck Massager adopts with human body cervical physiological curvature of the popular type circular design. Using low-frequency pulse, infrared light heating, U-Shaped Design, Ergonomic design and 3D intelligent bonding technology to form a composite energy field to achieve tetras health care and fit the neck in all directions, comfortable to wear and more satisfying. During the working process, maintaining the correct physiological position to provide healthy and cosy therapy for the cervical spine. With Neck Massager, you can enjoy a more valuable, relaxed and happy multifunctional health care system at any time and anywhere.  

    Add to Cart
    $69.00
  • Digital TENS/EMS Premier Combo Plus+24P
    The Premier Stim Plus TENS/EMS is a fully digital battery operated pulse generator that sends electrical impulses to the nerves and underlying muscle groups. This unit is a combination stimulator of TENS and EMS which can be used for pain relief and muscle stimulation. The device is provided with two controllable output channels, each independent of the other. A pair of electrodes can be connected to each output channel. The intensity level and settings are controlled by press buttons.

    Accessories:
    1. Adhesive Electrodes 4 pcs
    2. Electrodes Leads 2 pcs
    3. 9V Battery  1 pcs
    4. Blue Carrying Case 1 pcs
    5. English Operation Manual 1 pcs
    6. AC Power Cord 1 pcs
    7. Tens Electrodes Placement Chart 1 pcs
     


     

     

     

    MECHANISM

    TECHICAL DESCRIPTION

    01

    Channel

    Dual, isolated between channels

    02

    Pulse Amplitude
    Adjustable, 0-110 mA peak into 500 ohm load each channel.

    03

    Wave Form
    Asymmetrical Bi-Phasic Square Pulse

    04

    Voltage
    0 to 55V (Load: 500 ohm)

    05

    Power source
    One 9 Volt Battery.

    06

    Size
    11.8cm(L) x 6 cm(W) x 3.1cm(H)

    07

    Weight
    157 grams with battery.

    08

    Pulse Rate
    Adjustable, from 2 to 150 Hz, 1 Hz/step

    09

    Pulse Width
    Adjustable, from 50 to 300 microseconds, 10 µs/step

    10

    On Time
    Adjustable, 2~90 seconds , 1 Sec./ step

    11

    Off Time
    Adjustable, 2~90 seconds , 1 Sec./ step

    12

    Ramp Time
    Adjustable, 1~8 seconds, 1 Sec./ step, The "On"time will increase and decrease in the setting value.

    13

    Mode
    Six TENS Modes: B(Burst), N(Normal),M (Modulation Rate & Width),S1( Modulation Width), S2 (Modulation Width) and P Three EMS Modes:C(Constant), S (Synchronous), A(Alternate)

    14

    Burst Mode
    Burst rate: Adjustable, 0.5 ~ 5Hz
    Pulse width adjustable, 50~300 µs
    Frequency fixed = 100 Hz

    15

    Normal Mode
    The pulse rate and pulse width are adjustable. It generates continuous stimulation based on the setting value.

    16

    Modulation Mode
    Modulation mode is a combination of pulse rate and pulse width modulation. The pulse rate and width are automatically varied in a cycle pattern. The pulse width is decreased by 50% from its original setting in 0.5 second, then the pulse rate is decreased by 50% from its original setting in 0.5 second. Total cycle time is 1 second. In this mode, pulse rate(2-150Hz) and pulse width(50-300µs) are fully adjustable.

    17

    S1 Mode
    Pulse width is automatically varied in a cyclic pattern over a nominal 10 second period. Pulse width decreases over a period of 4 seconds from the initial setting to a value 40% less.
    The narrower pulse width continues for 1 second. It then increases over a period of 4 seconds to its initial setting. The cycle is then repeated. Pulse rate and pulse width are fully adjustable.
    18
    S2 Mode
    Pulse width is automatically varied in a cyclic pattern over a nominal 10 second period. Pulse width decreases over a period of 4 seconds from the initial setting to a value 70% less.
    The narrower pulse width continues for 1 second. It then increases over a period of 4 seconds to its initial setting. The cycle is then repeated. Pulse rate and pulse width are fully adjustable.
    19
    Constant Mode(C)
    The pulse rate and pulse width are adjustable. It generates continuous stimulation is delivered .
    20
    Synchronous Mode(S)
    Output from both channels occurs synchronously. The "ON" time includes "Ramp Up" and "Ramp Down" time. Therefore, the setting of ON Time should be no less than two times of the "Ramp" time in this mode.
    21
    Alternate Mode(A)
    The stimulation of the CH2 will occur after Mode(A) the 1st contraction of CH1 is completed. In this mode, the setting of ON Time should be no less than two times of the "Ramp" time. The OFF Time should be equal to or greater than the ON Time.
    ON TIME ≥ Ramp up + Ramp down
    OFF TIME ≥ IN TIME
    22
    Mode P

    The pre-set parameters of the 9 programs are as given below:

    Program
    Mode
    Pulse Rate
    Pulse Width
    Timer
    P1
    Constant
    80Hz
    180µs
    Continue
    P2
    Burst
    100Hz
    (Burst Rate:2Hz)
    180µs
    Continue
    P3
    -70% P.W.Modulation
    80Hz
    50µs-180µs
    Continue
    P4
    Mixed Frequency
    15Hz in 3 Sec 
    /2Hz in 3 Sec
    180µs
    Continue
    P5
    Mixed Frequency
    80Hz in 3 Sec /
    2Hz in 3 Sec
    180µs
    Continue
    P6
    Constant
    10Hz
    180µs
    Continue
    P7
    Constant
    80Hz
    60µs
    Continue
    P8
    Constant
    80Hz
    180µs
    30 Minutes
    P9
    Burst
    100Hz(Burst Rate:2Hz)
    180µs
    30 Minutes
    23
    Timer
    Adjustable, from 5 to 60 minutes minutes and continue(C), 5 minutes each step.
    24
    Patient 
    Compliance Meter
    This unit can store 60 sets of operation records. Total recorded time is 999 hours.
    25
    Low Battery Indicator
    A low battery indicator will show up when the battery is low.
    26
    Operating Condition
    Temperature:0°~40°C
    Relative Humidity: 30%~75%
    Atmosphere Pressure : 700Hpa~1060Hpa
    27
    Remark
    There may be up to a +/-10% tolerance of all parameters and +/-20% tolerance of output amplitude & voltage.
    Add to Cart
    $135.00
  • Adhesive Electrodes
    Self-Adhesive Electrodes for:

    - Transcutaneous Electrical Nerve Stimulator
    - Electrical Muscle Stimulator
    - Interferential Stimulator
    Add to Cart
    $10.00
  • Pain Relief Tens Electrodes Refill Kit
    This Electrode Refill Kit is to be used with the TENS Unit.

    The refill packages come with everything you see here. We recommend replacing the electrode pads once they do not stick well or they have been used for more than 30 days. The Refill package contains one conductive cable set (lead wire) and 3 sets of re-usable, latex-free electrode pads (6 individual pads). 

    The Refill Kit comes with:
    •  2" x 2" re-usable electrode pads (3 packages of 2)
    •  Conductive Cable (lead wire set)
    Add to Cart
    $18.00
  • Incontinence Stimulator

    The EM-2400 incontinence stimulator is a battery operated pulse generator that stimulates the muscles of the pelvic floor by means of a vaginal or rectal electrode. The unit has a single controllable channel which the electrode is connected to.

    The stimulator has 5 preset programmes. The programme type and the intensity of stimulation are controlled by push buttons. 
     
     

     

    MECHANISM

    TECHICAL DESCRIPTION

    01

    Channel
    Single channel

    02

    Pulse Amplitude
    Adjustable, 0-80mA, Max output 80mA (peak to peak) into 500ohm load.

    03

    Output Voltage
    Adjustable, 0-40V, Max output 40V (peak to peak) into 500ohm load.

    04

    Wave Form
    Asymmetrical Rectangular Biphasic Pulse.

    05

    Power Supply
    Two AA Batteries

    06

    Size
    9.2cm(L) x 6.2cm(W) x 2.85cm(H)

    07

    Weight
    145 grams (2 batteries included)

    08

    Pulse Rate
    Pre-setting, 1~100 Hz

    09

    Pulse Width
    Pre-setting, 150 µs, 200 µs or 250 µs

    10

    Programme
    A, B, C, D, E, five pre-set programme of options.

    11

    Programme 
    A ,B, C, E
    The programme details of A, B, C, E are as follows. Parameters are preset at fixed values. The 2 seconds ramp time includes 1 second ramp up, and 1 second ramp down. Each programme is repeated in a constant cyclic pattern.
    Programme
    Rate
    Width
    Contraction
    Relaxation
    Ramp
    Cycle
     
    (Hz)
    (µs)
    (Sec.)
    (Sec.)
    (Sec.)
    (Sec.)
    A
    35
    250
    4
    8
    2
    14
    B
    40
    200
    6
    15
    2
    23
    C
    10
    250
    5
    3
    2
    10
    E
    20
    250
    5
    5
    2
    12

    12

    Programme D
    Programme D is composed of 12 sections with varied pulse rates. Each section contains 30 contractions. The 2 seconds ramp time includes 1 second ramp up, and 1 second ramp down. The complete programme lasts 60 minutes with 360 contractions. It is repeated in a constant cyclic pattern. The details of the programme are given below.
    Section
    Rate
    Width
    Contraction
    Relaxation
    Ramp
    Cycle
     
    (Hz)
    (µs)
    (Sec.)
    (Sec.)
    (Sec.)
    (Sec.)
    1
    7
    150
    4
    4
    2
    10
    2
    8
    150
    4
    4
    2
    10
    3
    9
    150
    4
    4
    2
    10
    4
    10
    150
    4
    4
    2
    10
    5
    11
    150
    4
    4
    2
    10
    6
    12
    150
    4
    4
    2
    10
    7
    13
    150
    4
    4
    2
    10
    8
    14
    150
    4
    4
    2
    10
    9
    15
    150
    4
    4
    2
    10
    10
    16
    150
    4
    4
    2
    10
    11
    12
    150
    4
    4
    2
    10
    12
    7
    150
    4
    4
    2
    10

    13

    Timer
    Fixed at 30 minutes, treatment time countdown automatically. The output current will be shut off when the time is expired followed by  a beep sound.

    14

    Operating Condition
    Temperature:0° C ~ 40° C 
    Relative Humidity: 30%~75%
    Atmosphere Pressure: 700Hpa~1060Hpa

    15

    Remark